Brand Name : Mindray
Model Number : Biochemical Analyzer Light Source Bulb 12V20W BS350S 360S 810S 830S 870S 12V 20W
Certification : CE/CB/ROSH
MOQ : 1
Price : USD
Payment Terms : L/C, D/A, D/P, T/T
Packaging Details : Carton
Brand : Mindray
Color : Metal and glass
Category : Bulb
Wattanty : 90 Days
Packing weight : 1kg
size : Uniform size
Application area : Hospitals, private clinics, etc
Condition : new
Estimated Ship Time : 3-5 Business Days
In stock : Enough stock
Specification : 0.5x0.5cm
Used for : Biochemical Analyzer Light Source Bulb
net weight : 0.5 kg
Shape : standard
The light bulb (12V 20W) of the Mindray biochemical analyzer is a very important component in the Mindray BS-350S, BS-360S, BS-810S, BS-830S, and BS-870S clinical chemistry analyzers. If the light bulb of the analyzer malfunctions, it is necessary to consider replacing the light bulb of the biochemical analyzer in a timely manner. It is recommended to keep an extra light bulb when using a biochemical analyzer.
Specifications:
Voltage: 12V DC
Power: 20W
Base type: Consider whether it is a dual needle base. It is recommended to refer to the user manual of the biochemical analyzer
Filament type: halogen bulb
Service life: about 1000-2000 hours, depending on the machine's usage cycle. If used frequently, the light bulb will definitely need to be replaced in a timely manner when it reaches the end of its service life.
During the replacement process, it is necessary to pay attention to whether the biochemical analyzer equipment has triggered error codes, such as "light error" or "low light" alarms, and replace the light source bulb according to the prompts;
2. Some biochemical analyzers output spectra that match the wavelength, but the absorbance is not sufficient. In this case, it is necessary to replace the biochemical analyzer light source bulb in a timely manner, as absorbance is crucial for reading;
3. Regularly check whether there is corrosion on the base of the light bulb and the installation position of the biochemical analyzer light bulb. If there is corrosion, please pay attention to cleaning;
4. Regularly check whether the socket of the biochemical analyzer bulb is worn or loose, to prevent the bulb from flickering due to looseness and affecting the service life of the biochemical analyzer bulb;
5. Check the detection results of the biochemical analyzer. If the results are inconsistent, it may be a problem with the light bulb;
If the lifespan of the light bulb is approaching its service life, please replace it promptly with a brand new light source bulb. Simultaneously record the accurate time of bulb replacement.
Type: | Mindray Biochemical Analyzer Light Source Bulb 12V20W BS350S 360S 810S 830S 870S 12V 20W |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODLE: | 12V20W BS350S 360S 810S 830S 870S 12V 20W |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Metal and glass |
Delivery Date: | 3 - 5 Working Days |
Package | Carton |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.
![]() |
Mindray Biochemical Analyzer Light Source Bulb 12V20W BS350S 360S 810S 830S 870S 12V 20W Images |