Brand Name : Physio-Control
Model Number : 11996-000017
MOQ : One piece
Payment Terms : T/T, Western Union,Paypal
Delivery Time : 3-5 working days
Packaging Details : Carton
Product Name : 11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator
Brand : Physio-Control
Part No : 11996-000017
MOQ : One piece
Warranty : 90 days
Application : Physio-Control Lifepak 1000 Defibrillator
Patient Type : Adult
Patient Impedance Range : 10 – 300 ohms
Use for : Hospital ,Clinic
Condition : Original new
Physio-Control Lifepak 1000 Defibrillator Pads 11996-000017
► About Physio-Control Lifepak 1000 Defibrillator
Defibrillation is a recognized method of stopping life-threatening arrhythmias. DC defibrillators send short, high-energy electrical pulses to the heart muscle. The LIFEPAK® 1000 defibrillator is an automated external defibrillator (AED) that delivers this energy through disposable defibrillation electrodes placed on the patient's chest.
Defibrillation is only one aspect of the medical care required to resuscitate a patient with a shockable EKG rhythm. Depending on the circumstances, additional measures may include:
• Cardiopulmonary resuscitation (CPR)
• Supplemental oxygen
• Drug treatment
Successful resuscitation is known to be related to the time between non-circulating heart rhythms (ventricular fibrillation, pulseless ventricular tachycardia) and defibrillation. The American Heart Association has identified the following critical links in the sudden cardiac arrest (SCA) survival chain:
• Early attention
• Early resuscitation by paramedics or bystanders.
• Early defibrillation
• Early advanced life support
With Adult Pads:
Patient Impedance Range: 10 – 300 ohms
The following specifications apply from 25 to 200 ohms.
Energy Accuracy:
10% of the energy setting into 50 ohms
15% of the rated energy output into 25 – 200 ohms
Rated energy output is the nominal delivered energy based on the energy setting and patient impedance, as defined in the following chart.
► TROUBLESHOOTING TIPS FOR DEFIBRILLATION
Observation | Possible Cause | Solutions |
CONNECT ELECTRODES voice prompt is heard. | Poor electrode-to-skin contact. Electrode pads are dry, damaged, or have passed the expiration date. Electrode pads are not removed from the liner. | • Firmly press electrodes on patient’s skin. • Clean, shave, and dry the patient’s skin prior to placing pads on skin • Replace the electrode pads. • Remove the electrode pads from the liner and apply them to the patient’s chest |
► Specification of Physio-Control Lifepak 1000 Defibrillator Pads 11996-000017
Product Name | Physiillatoro-Control Lifepak 1000 Defibr Pads 11996-000017 |
Brand | Physio-Control |
Part No | 11996-000017 |
Application | Physiillatoro-Control Lifepak 1000 Defibrallator |
MOQ | One piece |
Warranty | 90 days |
Condition | Original new |
Use for | Hospital ,Clinic etc |
Patient Type | Adult |
Thank you so much for your attention .If you're interested in 11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator ,feel free to contact us .Thank you .
![]() |
11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator Images |