Mindray Rechargeable Li Ion Battery LI11S001A 3.7V 1800mAh 6.66Wh PN M05-010004-08 For Mindary DPM2 PM60 Pulse Oximeter

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Mindray Rechargeable Li Ion Battery LI11S001A 3.7V 1800mAh 6.66Wh PN M05-010004-08 For Mindary DPM2 PM60 Pulse Oximeter

Brand Name : Mindray

Model Number : LI11S001A

MOQ : 1

Payment Terms : T/T, Western Union,PayPal

Delivery Time : 3-5 working days

PRODUCT NAME : Mindray Rechargeable Li-ion battery

TYPE : M1943NLLI11S001A

APPLICATION : Mindary DPM2, PM60 Pulse Oximeter

WARRANTY : 90days

Key ward : Mindray battery

Product Type : battery

CONDITION : In Good Working Order

Rated voltage : 3.7V

Color : Black

Capacity : 1800 mAh

Weight : 47g / 1.66oz

Dimensions : 54.00 x 46.25 x 13.00mm

Charge time : 2 hours to 90% 3.5 hours to 100%

PN : M05-010004-08

Contact Now

Mindray Rechargeable Li-ion battery LI11S001A 3.7V 1800mAh 6.66Wh PN M05-010004-08 for Mindary DPM2, PM60 Pulse Oximeter

► Brief Introduction

Mindray Rechargeable Li-ion battery LI11S001A 3.7V 1800mAh 6.66Wh PN M05-010004-08 is work for Mindary DPM2, PM60 Pulse Oximeter.

If the battery capacity is too low, a technical alarm will be triggered and the [Battery Too Low] message displayed. At this moment, replace the the battery if a lithium ion battery is used. Otherwise, the pulse oximeter will shut down automatically when the battery is depleted. If interrupting patient monitoring is not allowed at this moment, you can place the pulse oximeter in the Charger stand and connect the AC mains. In this case, the pulse oximeter will give prompt message [Battery Type Err] if the alkaline batteries are used. You must pay close attention to the power supply to the pulse oximeter and replace the alkaline batteries or charge the lithium ion battery as soon as interruption of patient monitoring is permissible.

You can charge the lithium ion battery using a Charger stand whether the pulse oximeter is turned on or off. However, monitoring a patient while the battery is being charged is not recommended.

Specifications

Rated voltage 3.7V
Color Black
Capacity 1800 mAh
Weight 47g / 1.66oz
Dimensions 54.00 x 46.25 x 13.00mm
Run time 24 hours with SpO2 monitored continuously, audio indicators off and backlight brightness set to minimum using a new, fully charged battery at ambient temperature 25℃.
Charge time 2 hours to 90%
3.5 hours to 100%
Shutdown delay Max. 10 minutes after the low battery alarm first occurs.

When a lithium ion battery is used, the battery icon indicates the battery status as follows:

1.

Indicates that the battery works correctly. The solid portion represents the current charge level of the battery in proportion to its maximum charge level.

2.

Indicates that the battery has low charge level and need to be charged.

3.

Indicates that the battery is almost depleted and need to be charged immediately.

Conditioning the Lithium Ion Battery

A lithium ion battery needs at least two conditioning cycles when it is put into use for the first time. A battery conditioning cycle is one complete, uninterrupted charge of the battery, followed by a complete, uninterrupted discharge of the battery. A lithium ion battery should be conditioned regularly to maintain its useful life. Condition a battery once when it is used or stored for two months, or when its run time becomes noticeably shorter.
To condition a lithium ion battery, follow this procedure:

  1. Disconnect the pulse oximeter from the patient and stop all monitoring and measuring procedures.
  2. Place the lithium ion battery in need of conditioning into the battery compartment of the pulse oximeter
  3. Place the pulse oximeter in the Charger stand and connect the AC mains. Allow the battery to be charged uninterruptedly for above 2 hours.
  4. Remove the AC mains and allow the pulse oximeter to run from the battery until it shuts off.
  5. Replace the pulse oximeter in the Charger stand and connect the AC mains. Allow the battery to be charged uninterruptedly for above 2 hours.

Now, the battery is conditioned and the pulse oximeter can be returned to service.

If you have other questions about Mindray Rechargeable Li-ion battery LI11S001A 3.7V 1800mAh 6.66Wh PN M05-010004-08 for Mindary DPM2, PM60 Pulse Oximeter, please feel free to contact us. We are always ready to serve you.


Product Tags:

Mindray Rechargeable Li Ion Battery

      

LI11S001A Rechargeable Li Ion Battery

      

M05-010004 Rechargeable Li Ion Battery

      
Wholesale Mindray Rechargeable Li Ion Battery LI11S001A 3.7V 1800mAh 6.66Wh PN M05-010004-08 For Mindary DPM2 PM60 Pulse Oximeter from china suppliers

Mindray Rechargeable Li Ion Battery LI11S001A 3.7V 1800mAh 6.66Wh PN M05-010004-08 For Mindary DPM2 PM60 Pulse Oximeter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0